PDF Publication Title:
Text from PDF Page: 008
Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Capstone Model C60 Electrical, HEV Model Communications User Connections A wiring harness (W107) is provided from the Intra cable at connector J9 on the ECM Control board providing the interconnection means for contact closure inputs and 25 volt DC power supply. The data is presented in Table 5. Table 5. W107 Intra Connector - User Connection Inputs Wire Signal Parameter Red 25 VDC Power Supply input Power supply is required to power up the system prior to a start and through completion of Cooldown for battery voltages below 300 VDC. 24 to 26 VDC, 5 Amps Black 24 VDC Power Supply Ground Orange E-Stop Brown E-Stop Communications Ports Chassis grounded return for power of Red wire. Dry circuit contact closure. Closed for normal operation, open for E-Stop. (+) 25.4 VDC @ 42 mA Return for Orange wire, ground referenced Serial communications ports are available from the ECM Control Board (W103 harness) providing RS-232 communication for command, control and troubleshooting of the MicroTurbine. The data is presented in Table 6. Table 6. Serial Communication Ports Pin Signal Parameter I/O 1 I/O 2 User Interface Port Maintenance Interface Port DB9 (male polarity) and RS-232 protocol. Maximum null modem cable length is 50 feet. DB25 (male polarity) and RS-232 protocol. Maximum null modem cable length is 50 feet. 410031-001 Rev C (October 2004) Page 8 of 8 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the equipment ratings, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Technical Reference Capstone Model C60 Electrical, HEV Model
PDF Search Title:
Technical Reference Capstone Model C60 Electrical, HEV ModelOriginal File Name Searched:
410031_HEV60_Electrical.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)