Dual Mode Controller Application Guide

PDF Publication Title:

Dual Mode Controller Application Guide ( dual-mode-controller-application-guide )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 016

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 Application Guide: Dual Mode Controller (DMC) Dispatch Mode Operation Settings When the utility voltage is acceptable, the DMC will connect the MicroTurbine(s) and the Protected Loads to the utility. If the MicroTurbine Start Input is configured as REMOTE, the unit will act as a standby generator and will never start in Grid Connected mode. The MicroTurbine(s) will periodically charge the batteries using power from the utility. If the MicroTurbine Start Input is configured as GC USER/SA REMOTE, the unit will start and dispatch power in Grid Connect mode according to the settings for User Start, User Power Level, Time of Use, and Load Following. Refer to the MicroTurbine System Operation Manual for details of these dispatch control functions. The MicroTurbine(s) will periodically charge the batteries using power from the grid or from the engine if the MicroTurbine is operating. When a utility outage occurs, the DMC will isolate the MicroTurbine(s) and the Protected Loads from the utility and will automatically dispatch the MicroTurbine(s) to start in the Stand Alone mode, regardless of the Grid Connect dispatch control settings. Grid Connect-to-Stand Alone Transition The following Sequence of Events occurs during the automatic transfer from Grid Connect (GC) mode to Stand Alone (SA) mode. For additional information, please refer to the DMC schematic diagram in the Appendix to this document. 1. The utility voltage is acceptable. The under voltage relay in the DMC is not tripped. The DMC POWER Switch (S1) is set to ON and the MODE Switch (S2) is set to AUTO. The isolation switch (M1) is closed. The MicroTurbine(s) and the Protected Loads are connected to the utility. The MicroTurbine(s) are either in the stand-by state, or are operating in the Grid Connected mode, depending on the dispatch settings. 2. A utility outage begins. The under voltage relay in the DMC senses the utility outage, and then opens the normally open contacts UVR and closes the normally closed contacts UVR. 513000-001 (Oct 2001) Page 16 of 32 DMC Application Guide. Rev. A Capstone Turbine Corporation reserves the right to change or modify without notice the design, the equipment specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Dual Mode Controller Application Guide

PDF Search Title:

Dual Mode Controller Application Guide

Original File Name Searched:

513000 Dual Mode Controller_Dwgs.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)