Capstone Turbine Corporation  21211 Nordhoff Street  Chatsworth  CA 91311  USA Technical Reference: Capstone C60/C65 Electrical Table 5. Primary Settings/Adjustments: Stand Alone (Continued) Parameter Setting and/or Adjustment Voltage Start Voltage Ramp Frequency Start Frequency Ramp Auto Sleep Sets initial value of output starting voltage ramp: 0 volts to nominal voltage set point with 1-volt resolution. Default = 0 Sets rate-of-change of output starting voltage ramp: 3 to 6000 volts/second with 1 volt/second resolution. Default = 3000 Sets initial value of output starting frequency ramp: 0 Hz to nominal frequency set point with 0.1-Hz resolution. Default = 0 Sets rate-of-change of output starting frequency ramp: 1 to 2000 Hz/second with 1-Hz/second resolution. Default = 2000 Sets automatic sleep time. Default = 1 minute Protective Settings and Adjustments Protective settings and adjustments are used to shut down the output of the MicroTurbine should any abnormal conditions appear on the output. Refer to the Protective Relay Technical Reference for the applicable Protective Settings and Adjustments for both Grid Connect and Stand Alone modes of operation. Communications Bay The Communications Bay provides the interconnection means for serial communications, digital inputs, analog inputs, contact closure inputs and outputs, and 12 volt DC power for a modem and auxiliary load operation. The data is presented in Table 6 through Table15.  Table 6: Connectors J1 and J2 – MultiPac Communication Ports  Table 7: Connectors J3 and J5 – Serial Communication Ports  Table 8: Connector J6 – Inter-Controller (A) RS-485 Port  Table 9: Connector J8 – Inter-Controller (B) RS-485 Port  Table 10: Connector J10 – Miscellaneous I/O Connections  Table 11: Connector J11 – Opto-Isolated Inputs from Wattmeter  Table 12: Connector J12 – Contact Closure Inputs  Table 13: Connector J14 – Analog Inputs  Table 14: Connector J15 – Solid-State Relay Outputs  Table 15: Connector J16 – Modem and User Power Outputs 410001 Rev K (June 2009) Page 15 of 22 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Technical Reference Capstone Model C60/C65 Electrical

PDF Search Title:

Technical Reference Capstone Model C60/C65 Electrical

Original File Name Searched:

C60_C65_Elect_Tech_Ref1.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)