Troubleshooting with Fault Codes - Example The following sections present details of various fault codes, their meanings, and a sequential approach for troubleshooting the MicroTurbine system using the fault codes. The basic trouble- shooting format is the same for all fault codes. 3006 Internal Warning TCIN OP Compressor Inlet Thermistor Open System Severity Level 2 For example, the procedure for Fault Code 3006 is explained below. Note that only the top three probable causes, analyses, and repair solutions are shown in the following table. (Refer to Series 3000 Fault Codes section for more details.) The thermistor inputs are expected to measure within a specified range. Values outside this range indicate hardware circuitry problems. The software declares a Compressor Inlet Thermistor Open condition when it reads less than -51 °C (-60 °F). Symptom Probable Cause Analysis Repair Solution Low Temperature Reading Low Ambient Temperature See system specifications Increase temperature where system is installed Faulty Harness Connection Check Engine harness from J4 on ECM Control Board to ACM connector J1, and compressor inlet thermistor harness from ACM connector J2 to the thermistor. Secure connection or replace harness Defective Thermistor Connect a known good thermistor to system and verify accurate ambient reading to determine if thermistor needs replacement. Replace Thermistor The above table has four column heads, i.e., Symptom, Probable Cause, Analysis, and Repair Solution. Referring to the above table, proceed with the following troubleshooting sequence: 1. Check the Symptom column. For this example, it shows Low Temperature Reading. 2. Check the Probable Cause column. Three probable causes are shown for this symptom. Start with the first one which is: Low Ambient Temperature. To verify this, go to the Analysis column and follow the respective instruction which is: See system specifications. If the probable cause is verified, go to the Repair Solution column and follow the respective instruction which is: Increase temperature where system is installed. 3. If the probable cause is not Low Ambient Temperature, then go down to the second probable cause which is: Faulty Harness Connection. To verify this, go to the Analysis column and follow the instruction which is: Check Engine harness from J4, etc.... If the probable cause is verified, go to the Repair Solution column and follow the instruction which is: Secure connection or replace harness. 4. If the probable cause is not Faulty Harness Connection, go down to the third, fourth, or other probable causes in sequence and follow instructions in Analysis and Repair Solution columns as required. Use the foregoing procedure for troubleshooting all other fault codes as required. Observe Safety Precautions - Refer to Safety Instructions for Details 430013-001 Rev C (July 2003) 1-23 Model C60 Troubleshooting Guide This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Table of Contents for Series Fault Codes
PDF Search Title:
Table of Contents for Series Fault CodesOriginal File Name Searched:
C60_01A_Front Section.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)