PDF Publication Title:
Text from PDF Page: 019
List of System Fault Codes The following tables list all of the fault codes used on the Model C60 MicroTurbine system. The table includes a brief description of each code and its system severity level (SSL). Fault No Description SSL Fault No Description SSL 1000 MAIN CSUM 7 3009 TCIN LO TEMP 2 1001 MAIN CPU FAULT 7 3010 FUEL TEMP OP 2 1002 MAIN RAM FAULT 7 3011 SPARE TC 1 SH 2 1003 CB MEM CSUM 7 3012 SPARE TC 2 OP 2 1004 WATCHDOG FAIL 7 3013 SPARE TC 2 SH 2 1005 CB EEPROM RD 2 3014 BOARD TEMP HI 3 1006 CB EEPROM WR 2 3015 BOARD TEMP LO 2 1007 ADC ACC LO 3 3016 BOARD TEMP OP 3 1008 ADC ACC HI 3 3017 BOARD TEMP SH 3 1009 ADC CONVERT 3 3018 PWR SUPPLY HI 2 1010 5V REGULATOR 7 3019 PWR SUPPLY LO 2 1011 RTC FAULT 2 3020 SPEED DELTA 3 3021 PAMB FAILED 2 3022 PAMB SH 2 2000 VENT FAN DRV 3 3023 PAMB LOW 2 2001 VENT FAN SH 3 3024 LO FUEL PRESS 3 2002 HTSK FAN DRV 3 3025 HI FUEL PRESS 2 2003 HTSK FAN SH 3 3026 LO FUEL AIRPRS 3 2004 CNTCTR 3 3027 HI FUEL AIRPRS 3 2005 CNTCTR SH 3 3028 AA VLV STUCK 7 2006 PB EEPROM RD 2 3029 RFC AIR ASSIST 3 2007 PB EEPROM WR 2 3030 AA AIR PRESS HI 3 2008 PB EEPROM CSUM 7 3031 RFC LO FUEL PRES 3 2009 GEN IGBT 6 3032 RFC PRS CAL ERR 3 2010 INV IGBT 5 3033 RFC PRS ACC ERR 2 2011 INV IGBT NEUT 5 3034 LCM BRD TEMP HI 3 2012 BRAKE FAILED 6 3035 LCM BRD TEMP LO 2 3036 LCM BRD TEMP OP 3 3037 LCM BRD TEMP SH 3 3000 TET1 OP 2 3038 GDSP PWRSP OTMP 3 3001 TET1 SH 2 3002 TET2 OP 2 3003 TET2 SH 2 4000 WATCHDOG TO 7 3004 BOTH TET 3 4001 BUFFER OVERFLOW 2 3005 TET DELTA 2 4002 ENG TSK OVRN 1 3006 TCIN OP 2 4003 SYS TSK OVRN 1 3007 TCIN SH 2 4004 IDSP TSK OVRN 1 3008 TCIN HI TEMP 2 4005 IDSP BLTSK OVRN 2 Observe Safety Precautions - Refer to Safety Instructions for Details 430013-001 Rev A (October 2002) 15 Model C60 Troubleshooting Guide This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Table of Contents for Series 1000-12000 Fault Codes
PDF Search Title:
Table of Contents for Series 1000-12000 Fault CodesOriginal File Name Searched:
C60FaultCodes.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)