Capstone Turbine Corporation UPS Controller User’s Manual Troubleshooting Troubleshooting the UPS Controller Most of the common faults associated with the controller may be related to power or communication connections between the controller and the Hybrid UPS MTs or the controller and the building management system. Troubleshooting a Controller That Will Not Wake Up 1. If the display screen is dark, tap it on any point to wake it up. Note that the display panel has a screen save feature, which will cause the screen to turn off after 30 minutes of inactivity. 2. If the display screen does not light up after tapping it, the entire controller may be asleep. a. Press the wakeup button located on the front panel to wake up the controller. If no activity is seen on the screen after pressing the wakeup button, there may be a power supply problem in the controller. Check the circuit breaker or disconnect providing power to the controller and make sure it is in the ON position. b. If all external power connections to the controller are good, open the controller front door and look for the 120-240 VAC to 24 VDC power supply. Make sure that the green LED labeled OK is lit. If this LED is not lit, using a voltmeter, check the AC input voltage for the power supply by placing the voltmeter leads on the L and N terminals at the bottom of the power supply. If the voltage is between 110 VAC and 240 VAC, then the power supply must be replaced. c. If the 24 VDC power supply is good, check the UPS power supply to the right of the 24 VDC power supply. Check that the Input Power OK LED is lit. If it is not lit, measure the input of the UPS power supply with the voltmeter. It should read about 24 VDC. If the input voltage reads 24 VDC, but the Input Power OK is not lit, the DC UPS needs to be replaced. If the Input Power OK LED is lit, press the white ON/OFF/TEST button on the power supply for 5 seconds and measure the Load voltage output. The load voltage output should read 24 VDC. Troubleshooting a Controller That Will Not Respond to Local and Remote Commands If a remote command is issued to the controller and the controller has not responded to the commanded state from the DCS within 15 seconds, this may be due to communication issues between the controller and DCS. On the Maintenance screen shown in Figure 6, check that the DCS Commanded Mode corresponds to the desired mode of operation. If it does not, check that the DCS is set for the desired method of operation. Also check that Communications are enabled. If the communications are disabled, press the enable button. Communications must be enabled all the time. The only instance where communications may be disabled is when the system is down for software maintenance. If the DCS Commanded Mode is UPS Normal or High Efficiency and the Mode Response and Current State do not follow the DCS commanded mode within 15 seconds, contact your Authorized Service Provider. Page 32 of 35 400028 Rev B (January 2014) Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Hybrid UPS Controller User's Manual
PDF Search Title:
Hybrid UPS Controller User's ManualOriginal File Name Searched:
400028B_UM_HUPS_CONTROLLER.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)