Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Application Notes: Fuel Gas Booster Installation Instructions – Model C60 LPNG 3. Prepare the high power electrical interface connections as follows (reference Figure 1): a. The high power electrical leadwires must be 14 AWG, 600V, Red (+), Black (-), and Green/Yellow (GND). The wiring should be enclosed within a 1/2-inch, weatherproof, flexible steel conduit. b. The Fuel Gas Booster high power electrical leads are to be connected to the DC bus on the controller. The high power electrical leads should be connected at the rear of the unit as shown in Figure 1. WARNING When connecting the Fuel Gas Booster DC Bus high power electrical leads, ALWAYS connect the Fuel Gas Booster side FIRST, and then connect the MicroTurbine side. CAUTION BE SURE to correctly connect the polarity on the DC Bus. Incorrectly connecting the DC Bus will cause damage to the Fuel Gas Booster. 4. Connect the Fuel Gas Booster high voltage terminals to the MicroTurbine DC bus. CAUTION BE SURE that the metallic conduit is grounded to the chassis at both the MicroTurbine and the Fuel Gas Booster. 5. Power up the MicroTurbine. 512001-001 Rev C (March 2004) Page 4 of 8 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Fuel Gas Booster Installation Instructions Model C60 MicroTurbine - Low Pressure Natural GasApplication Notes
PDF Search Title:
Fuel Gas Booster Installation Instructions Model C60 MicroTurbine - Low Pressure Natural GasApplication NotesOriginal File Name Searched:
512001_C60_Vertical_FGB_App_Notes.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)