Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Dual Mode System Controller (DMSC): User’s Manual Table 2. MODE Switch Settings Mode Switch Position Description GRID MicroTurbines may be operated in Grid Connect mode only. During a utility outage, the MicroTurbines shut down and protected loads do not receive power. AUTO The MicroTurbines operate automatically in Grid Connect mode when the utility lines are energized, and in Stand Alone mode during a utility outage. Transition times between modes depend on system settings. TURBINE The MicroTurbines may be operated in Stand Alone only. Power from the MicroTurbines (24 VDC) is used to trip the remote disconnect device and prevent automatic reclosure. MANUAL RESET Switch The MANUAL RESET switch is used to reset the shunt trip of the remote disconnect device after it has been tripped for any reason other than a trip signal from the DMSC. The REMOTE TRIP lamp should extinguish when the MANUAL RESET switch is pressed. LINE POWER OK Indicator Lamp The LINE POWER OK lamp illuminates when the utility voltages are at an acceptable level and of the correct rotational sequence (L1-L2-L3). If the LINE POWER OK lamp does not illuminate when the DMSC is first energized by the utility, check the utility supply for both correct voltage and for correct rotational sequence. LOAD POWER OK Indicator Lamp The LOAD POWER OK lamp illuminates when protected loads are energized by either the utility or the MicroTurbines. MICROTURBINE AWAKE Indicator Lamp The MICROTURBINE AWAKE lamp illuminates when the DMSC is receiving 24 VDC from the MicroTurbine. In a MultiPac system, this lamp illuminates when the master MicroTurbine controls are energized. SWITCH CLOSED Indicator Lamp The SWITCH CLOSED lamp illuminates to indicate that the switch of the remote disconnect device is closed. In the closed position, the protected loads are connected to the utility. SWITCH OPEN Indicator Lamp The SWITCH OPEN lamp illuminates to indicate that the switch on the remote disconnect device is open. In the open position, the protected loads are disconnected from the utility. REMOTE TRIP Indicator Lamp The REMOTE TRIP lamp illuminates when the shunt trip of the remote disconnect device has been tripped by any device other than the DMSC. 400023 Rev A (October 2008) Page 15 of 27 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | DUAL MODE SYSTEM CONTROLLER (DMSC) USER’S MANUAL
PDF Search Title:
DUAL MODE SYSTEM CONTROLLER (DMSC) USER’S MANUALOriginal File Name Searched:
400023A_Dual_Mode_System_Controller_UM.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)