PDF Publication Title:
Text from PDF Page: 018
Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Dual Mode Controller (DMC): User’s Manual Grid Reconnect Toggle Use CRMS or the Display Panel and make sure that Grid Reconnect is set to AUTO, which is the default. This option does not apply to the C30 model, or to the C60 model with software v4.3X and lower. Stand Alone (SA) Load Wait Use CRMS or the Display Panel to enter a value in the range of 5 to 30, in minutes, for the SA Load Wait time. The default, and minimum, value is 5. This option is available in CRMS version 4.5X and higher, and it does not apply to the C30 model, or to the C60 model with software version 4.3X and lower. SA Fast Transfer Delay Use CRMS or the Display Panel to enter a value in the range of 0 to 30, in minutes, for the SA Fast Transfer Delay time. The default, and minimum, value is 0. This option is available in CRMS version 4.5X and higher, and it does not apply to the C30 model, or to the C60 model with software version 4.3X and lower. Auto Enable Power Use CRMS or the Display Panel to set Auto Enable Power (Auto Load on the Display Panel) to ON (YES on the Display Panel). This can also be done with the RS-232 command AUTOLD = 1. The default is OFF or 0 (NO on the Display Panel). For the C60/C65 model with software version 5.XX and higher, this option is not available on the Display Panel and must be set using CRMS. Start Input Use CRMS or the Display Panel to set Start Input to Remote SA/User Grid Connect (GC_User/SA_Remote on the Display Panel). This can also be done with the RS-232 command STRINP = 2. The default setting for Start Input is User, or 0. For the C60/C65 model with software version 5.XX and higher, this option is not available on the Display Panel and must be set using CRMS. UCB Output Relay Settings Use CRMS or the Display Panel to make the necessary settings (refer to Table 6) to the applicable UCB output relay as follows: Any output relay (1-6) can be selected, but the selected number must match the UCB to DMC connections. 1. Select the number of the UCB output relay that is connected to the DMC. Refer to the DMC Technical Reference (410039) for wiring data. 2. Set the selected output relay to ACTIVE CLOSED. 3. Set the selected output relay to Stand Alone LOAD (DUAL MODE CNTRL). These settings can also be done with an RS-232 command as described in the notes below. For the C60/C65 model with software version 5.XX and higher, this option is not available on the Display Panel and must be set using CRMS. 400009 Rev A (May 2008) Page 18 of 21 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction. NOTEPDF Image | DUAL MODE CONTROLLER (DMC) USER’S MANUAL
PDF Search Title:
DUAL MODE CONTROLLER (DMC) USER’S MANUALOriginal File Name Searched:
400009A_DMC_Users_Manual.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)