Overview SERIES 8000 FAULT CODES Solenoid Faults

PDF Publication Title:

Overview SERIES 8000 FAULT CODES Solenoid Faults ( overview-series-8000-fault-codes-solenoid-faults )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 045

10036 Internal Fault IDSP SNSR CAL Inverter Sensor Calibration failure System Severity Level 4 Symptom Probable Cause Analysis Repair Solution The DC offset of the output current sensors determined during the calibration period exceeds the maximum current sensor offset. The maximum current sensor offset is wrongly set. Make sure that the power board PM is programmed properly, and it is supported by the installed control software. Re-program the power board PM. Open/Loose Connection Check the connection of the cable that connects the port J15 of the DPC control board. Tighten cable connections Faulty DPC Control Board DPC Control Board needs replacing. Replace DPC Control Board (See Document 513176) Faulty DPC Power Board DPC Power Board needs replacing. Replace DPC Power Board 10037 Internal Fault IDSP PRECHARGE Inverter Failed to Precharge System Severity Level 4 Symptom Probable Cause Analysis Repair Solution In Grid Connected operation, the DC bus is not precharged by the end of the Grid Synchronization Time- out Time. The control para- meter of Grid Synchronization Time- out is wrongly set. Make sure that the power board PM is programmed properly, and it is supported by the installed control software. Re-program the power board PM. Open/Loose Connection Open the DPC cover and check if the wires between the line-filter & precharge board. Tighten cable connections The pre-charge resistors are burnt. Open the DPC cover and check the condition of the precharge resistors. Replace the line-filter & precharge board. Faulty DPC Control Board DPC Control Board needs replacing. Replace DPC Control Board (See Document 513176) Faulty DPC Power Board DPC Power Board needs replacing. Replace DPC Power Board Observe Safety Precautions - Refer to Important Safety Instructions for Details 430001-001 Rev A (Apr 2002) 181 Troubleshooting Guide Capstone Turbine Corporation reserves the right to change or modify without notice the design, the equipment specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Overview SERIES 8000 FAULT CODES Solenoid Faults

PDF Search Title:

Overview SERIES 8000 FAULT CODES Solenoid Faults

Original File Name Searched:

C330TroubleBook3Apr02.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)