Technical Reference Liquid Fuel System Technical Information – Model C30 MicroTurbine

PDF Publication Title:

Technical Reference Liquid Fuel System Technical Information – Model C30 MicroTurbine ( technical-reference-liquid-fuel-system-technical-information )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 010

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Liquid Fuel System Technical Information – Model C30 MicroTurbine Liquid Fuel Diagnostic Faults The following table summarizes possible liquid fuel system diagnostic faults. Detailed explanation of Liquid Fuel Controller Faults is available in the MicroTurbine Model C30 Troubleshooting Guide (430000). NOTE Fault No. 6006 6011 6012 Fault No. 16000 16001 16002 16003 16004 16005 16006 16007 16008 16009 16010 16011 16012 16013 16014 16018 16019 16020 16021 Engine Faults Fault Description SSL FAIL TO LIGHT 3 FLAMEOUT START 3 FLAMEOUT LOAD 3 Liquid Fuel System Faults Fault Description SSL PMP NOT PRIMED 3 FAIL TO PRIME 3 LF DRNTNK LVL 2 LF DRNTNK FULL 6 LF FAIL LINFIL 3 FAIL TO DRAIN 3 LF FUEL SOL 3 LF DRAIN SOL 3 LF PURGE SOL 3 LF STRTAIR SOL 3 LF BRD OTMP 3 LF BRDTMP SENS 3 LF COMM TO 3 LF XDUCER OP 3 LF XDUCER SH 3 LF INJ 1 CLGD 3 LF INJ 2 CLGD 3 LF INJ 3 CLGD 3 LF MULT INJ CLGD 3 410017-001 Rev C (February 2004) This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change Isolation Message Internal Fault Internal Fault Internal Fault Isolation Message Fuel Fault Fuel Fault Fuel Warning Fuel Fault Fuel Fault Fuel Fault Fuel Fault Fuel Fault Fuel Fault Fuel Fault Fuel Fault Fuel Fault Fuel Fault Fuel Fault Fuel Fault Fuel Fault Fuel Warning Fuel Warning Fuel Fault Page 10 of 12 shall be copied, disclosed to others, or used for any or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Technical Reference Liquid Fuel System Technical Information – Model C30 MicroTurbine

PDF Search Title:

Technical Reference Liquid Fuel System Technical Information – Model C30 MicroTurbine

Original File Name Searched:

410017_ELOR_Tech_Ref.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)