Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Liquid Fuel System Technical Information – Model C30 MicroTurbine Commissioning the System Fuel Pressure Requirements Inlet fuel pressure requirements are: -34 kPa (–5 psig) to 34 kPa (+5 psig). This range of inlet pressures accommodates differences in fuel tank placement (e.g. above ground, below ground, and distance of separation). Supply pressure must remain stable within ±2% of the nominal pressure (within the specified minimum-to-maximum pressure range) for the entire load range operation of the MicroTurbine system. Hardware Preparation Perform the following hardware checks in preparation for MicroTurbine priming: 1. The drain tank outlet shutoff valve (510575) on the package outlet should be replaced with a fitting (507025) to attach a drain line, if fuel will be returned to an external tank. Fuel may leak through the adjustment screw shaft of the drain tank outlet shutoff valve during tank draining if the fitting is not installed. Drain Tank Outlet Shutoff Valve Fitting 507025 2. Verify that any external fuel shutoff is open, and the fuel source is securely attached before initiating the start sequence on the MicroTurbine. 3. Initiate a start command to begin system operation and enter a 30 kW Demand to verify system operation. Note the system power level for future reference. WARNING Be careful not to introduce any dirt, debris or contaminants into the fuel system. Introducing contaminants may cause clogged fuel system injectors, leading to system failures. NOTE NOTE A “16004 FAIL TO LINEFILL” or “6006 FAIL TO LIGHT” fault may occur on the initial start sequence while air is initially pumped through the fuel system. If this occurs, perform another start command. 410017-001 Rev C (February 2004) Page 6 of 12 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Technical Reference Liquid Fuel System Technical Information – Model C30 MicroTurbine
PDF Search Title:
Technical Reference Liquid Fuel System Technical Information – Model C30 MicroTurbineOriginal File Name Searched:
410017_ELOR_Tech_Ref.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)