PDF Publication Title:
Text from PDF Page: 015
Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Capstone Model C30 Electrical Primary Settings/Adjustments: Stand Alone Table 5 presents the Primary Settings and Adjustments for the Stand Alone configuration. Parameter Setting and/or Adjustment Voltage Frequency Auto Load Auto Restart Voltage Start Voltage Ramp Frequency Start Frequency Ramp Auto Sleep Table 5. Primary Settings/Adjustments: Stand Alone Sets output voltage: 150 to 480 volts (line-to-line) with 1-volt resolution. Default = 480 Sets output frequency: 10 to 60 Hz with 0.1-Hz resolution. Default = 60 Enables/disables the presence of output voltage when Load state is achieved. (Enable/Disable) Automatically restarts after event-driven shutdown: (Yes/No). Default = No (The maximum number of auto restarts is 5, after which restarting will be locked out.) Sets initial value of output starting voltage ramp: 0 volts to nominal voltage set point with 1-volt resolution. Default = 0 Sets rate-of-change of output starting voltage ramp: 3 to 6000 volts/second with 1 volt/second resolution. Default = 3000 Sets initial value of output starting frequency ramp: 0 Hz to nominal frequency set point with 0.1-Hz resolution. Default = 0 Sets rate-of-change of output starting frequency ramp: 1 to 2000 Hz/second with 1-Hz/second resolution. Default = 2000 Sets automatic sleep time. Default = 1 minute Auto Restart Delay Delays the beginning of the restart sequence following an automatic restart command by 0.0 minutes to 60.0 minutes with 0.1-minute resolution. (The maximum number of sequential restarts is 5, before restarting is locked out.). Default = 0 Protective Settings and Adjustments Protective settings and adjustments are used to shut down the output of the MicroTurbine should any abnormal conditions appear on the output. Refer to the Protective Relay Technical Reference for the applicable Protective Settings and Adjustments for both Grid Connect and Stand Alone modes of operation. 410000 Rev. H (April 2006) Page 15 of 22 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the equipment ratings, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Technical Reference Capstone Model C30 Electrical
PDF Search Title:
Technical Reference Capstone Model C30 ElectricalOriginal File Name Searched:
410000_Model_C30_Electrical_Tech_Ref.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)