PDF Publication Title:
Text from PDF Page: 019
Pin Signal Parameter TB3-1 through TB3-12 Table 8. Terminal Board TB3 – Analog Inputs (Not Applicable) Reserved Table 9. Terminal Board TB4 – Digital Inputs Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Capstone Model 330 Electrical Pin Signal Parameter TB4-1 TB4-2 TB4-3 TB4-4 TB4-5 TB4-6 TB4-7 TB4-8 TB4-9 TB4-10 TB4-11 Digital input: OPTO 2 RTN Digital input Digital input Interlock Digital input Interlock Digital input Digital input Digital input Digital input Power return 5: Grid Connect 6: Stand Alone 4: External Fault #2 return 3: External Fault #1 2: Negative Reactive Digital ground return for TB4-2 and -3 Dry circuit closure from (+) 5 VDC pull-up, 1 kohm Dry circuit closure from (+) 5 VDC pull-up, 1 kohm Dry circuit closure from (+) 5 VDC pull-up, 1 k ohm Digital ground return for TB4-6 and TB4-7 Opto-isolated (±150 VDC maximum to earth) dry circuit closure from (+) 5 VDC pull-up, 1 k ohm 5 VDC pull up 1 k ohm through dry circuit closure in KYZ optional power meter 5 VDC pull up 1 k ohm through dry circuit closure in KYZ optional power meter Opto-isolated return for the signal of TB4-10. Opto-isolated (±150 VDC maximum to earth) input +4 to +15VDC. Opto-isolated return for the signal of TB4-12. Opto-isolated (±150 VDC maximum to earth) input +4 to +15VDC. Digital input Power 1: Positive Reactive Digital input OPTO 3 RTN Digital input (mimics DI # 3) OPTO 3 TB4-12 Digital input OPTO 2 (mimics DI # 2) Pin Signal Parameter TB5-1 AC1-A TB5-2 AC1-B TB5-3 AC2-A TB5-4 AC2-B TB5-5 AC3-A TB5-6 AC3-B TB5-7 AC4-A TB5-8 AC4-B TB5-9 AC5-A TB5-10 AC5-B TB5-11 AC6-A TB5-12 AC6-B Table 10. Terminal Board TB5 – Solid State Relays AC1 line, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC1 load, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC2 line, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC2 load, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC3 line, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC3 load, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC4 line, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC4 load, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC5 line, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC5 load, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC6 line, 132 VAC (Note 1) maximum voltage, 100 mA maximum current AC6 load, 132 VAC (Note 1) maximum voltage, 100 mA maximum current Note 1: When switching inductive loads, the solid-state relay outputs must be fitted with voltage suppression devices to limit the voltage transients to less than ± 300 V peak. 410000-001 Rev A (April 2002) Page 19 of 22 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the equipment ratings, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | 410000 C30 Elec
PDF Search Title:
410000 C30 ElecOriginal File Name Searched:
410000-Model-C30-Electrical.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)