PDF Publication Title:
Text from PDF Page: 026
Capstone Turbine Corporation Model C200 User’s Manual Clear Fuel Fault Submenu System Data 1/4 Clear Fuel Fault 3/10 NO Capstone The Clear Fuel Fault clears a fault originated by the fuel vent system which causes a MT shutdown. The user must electrically energize the MT, then activate the ‘Clear Fuel Fault’ which clears the fault. Then the user must do a Reboot. The cause of this fault may be a leak in the system, so troubleshooting and leak detection must be done immediately. Note that the user must be logged in with the current password to clear the faults. Vent Monitor Submenu System Data 1/4 Vent Monitor 4/10 YES C200 MicroTurbines include a fuel vent monitor that will activate an automatic shutdown if the seal on the fuel metering valve fails with gaseous fuel in the system. The default setting for the fuel vent monitor option is YES, and this setting should never need to be changed. However, the vent monitor option can be set to NO by a Capstone Authorized Service Provider for MicroTurbine repair or testing. System Configuration Submenu The System Configuration submenu contains system settings and allows the user to adjust the third level data, as detailed below: Power Connect Submenu System Data 1/4 System Config 5/10 Power Connect 1/4 Dual Mode The Power Connect submenu allows the user to change the operating mode of the MicroTurbine. Note that the user must be logged in with the current password to change the operating mode. • Invalid State (Initial Factory Setting) • Stand Alone • Grid Connect • Dual Mode The initial Factory Setting of “INVALID” is intended to ensure the true Power Connect option is set to match your specific application. Page 26 of 60 400008 Rev B (July 2008) Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction. NOTEPDF Image | Capstone MicroTurbine Model C200 User's Manual
PDF Search Title:
Capstone MicroTurbine Model C200 User's ManualOriginal File Name Searched:
400008B_C200_MicroTurbine_UM.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)