CAPSTONE C200 MICROTURBINE TECHNICAL REFERENCE

PDF Publication Title:

CAPSTONE C200 MICROTURBINE TECHNICAL REFERENCE ( capstone-c200-microturbine-technical-reference )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 071

Capstone CHAPTER 8 ELECTRICAL RATINGS Description Single Unit MultiPac Grid Frequency Acquisition Range 45 - 65 Hz. Auto synchronization. The microturbine senses the grid waveform and synchronizes to its phases and frequency before an output connection is made. Same as Single Unit Nominal Real Power Output @ ISO (Note 2) 0 to 200 kW HP NG 0 to 190 kW LP NG 75 to 200 kW HP Landfill Gas 75 to 200 kW HP Digester Gas kW = N * kWMT Apparent Power Output @ ISO Output Power Factor to Grid Typical Output Power Slew Rate Output Current Harmonic Content Output Current DC Content Grid Fault Current Contribution by microturbine Power Required @ Start Command Cooldown Power (Note 4) Draw in Standby Power Grounding (Note 5) Surge Voltage Withstand Short Circuit Rating Notes: kVAMT = kWMT (above) ± 0.985 displacement PF, for loads > 25% of rated load ± 6 kW/second, for natural gas; ± 2kW/sec for Landfill/Digester Gas Complies with IEEE 519, UL1741: < 5% THD. See Figure 8-1. <0.5% (1.4 Amps) DC (per UL 1741) 500 Amps RMS, maximum symmetrical and asymmetrical 20 kW peak, 0.13 kW-Hr, 70 Seconds No net utility power 300 seconds .30 kW Grid must be Neutral grounded. ± 6 kV (ANSI 62.41) Per UL 508C, the microturbine is not short circuit rated (Note 6) kVA = N * kVAMT Same as Single Unit ± N*Single Unit kW/second Same as Single Unit < N*1.4 Amps DC (UL 1741) N*500 Amps RMS, maximum symmetrical and asymmetrical kW = N*single unit Time same as single unit kW = N*single unit Time same as single unit N*.30 kW Same as Single Unit Same as Single Unit Same as Single Unit Maximum Output Current (Note 3) 230 Amps RMS @ 480V LP NG 240 Amps RMS @ 480 V all others 275 Amps RMS @ 400 V LP NG 290 Amps RMS @ 400 V all others N*Single Unit Amps RMS (1) Total harmonic voltage must be less than 5% (13.9 VRMS line-to-neutral for a 480 V system). Also, the high frequency ripple voltage must be less than 2% (5.5 VRMS line-to-neutral for a 480 V system) at frequencies greater than 3 kHz. (2) Refer Chapter 7: Performance for real power capability as a function of ambient temperature, elevation, and other site conditions. (3) The maximum currents are limited by the real power capability of the microturbine. Values listed are for full power at ISO conditions. Refer to Chapter 7: Performance for real power capability as a function of ambient temperature, elevation, and other site conditions. (4) Any load connected to the auxiliary contactor is in addition to the motoring loads shown in order to keep the microturbine in cooldown. (5) Refer to Chapter 12: Installation for additional details. (6) UL 1741 test-rated short circuit is 500 ARMS. 410066 Rev C (June 2009) 8-2 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | CAPSTONE C200 MICROTURBINE TECHNICAL REFERENCE

PDF Search Title:

CAPSTONE C200 MICROTURBINE TECHNICAL REFERENCE

Original File Name Searched:

410066C_C200_Tech_Ref.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info