PDF Publication Title:
Text from PDF Page: 061
CHAPTER 7 Capstone PERFORMANCE Example Calculations Table 7-5 provides an example calculation for a C200 low pressure natural gas microturbine operating at 30 C (86 F), 1,500 ft elevation, 2 inches WC inlet pressure loss, and 3 inches WC exhaust back pressure. Table 7-5. Example Calculation for Nominal Power, Efficiency, and Exhaust Characteristics Steps Rule Example 1. Define output power, efficiency, and exhaust characteristics at ambient temperature and sea level Use Table 7-2 For 86 F (30 C) Ambient: Output = 186 kW electric Efficiency = 31.7% Exhaust Temp = 570 F Exhaust Flow = 2.87 lbm/s 2. Estimate electric output at the given elevation 5. Calculate Nominal Net Power Output 6. Calculate Nominal Net Efficiency 7. Calculate Fuel Input 8. Consider Parasitic Loads Use Figure 7-2 kW (net) = kW (step 2) X Inlet CF X Exhaust CF Efficiency (net) = Efficiency (step 1) X Inlet CF X Exhaust CF Fuel [kW] = kW(net)/ Efficiency (net) Subtract parasitic loads, if any for 1,500ft Elevation: Output = 176 kW electric For Example Above: kWnet = 172 kW For Example Above: Efficiency (net) = 31.3% For Example Above: Fuel [kW] = 550 kW (or 1,880,000 BTU/hr) For Low Pressure NG: Parasitic = 10 kW Useable Power = 162 kW 3. Estimate Power and Efficiency Correction Factors for Inlet Pressure Loss Use Table 7-3 for 2 inch WC: Power CF = .987 Efficiency CF = .995 4. Estimate Power and Efficiency Correction Factors for Exhaust Back Pressure Use Table 7-4 for 3 inch WC: Power CF = .988 Efficiency CF = .993 9. Estimate Exhaust Characteristics Temp = Temp from step 1 Flow = Flow from step 1 times kWnet/kW step 2 less .5% per 1,000 ft Elevation Exhaust Temp = 570 F Exhaust Flow = 2.7 lbm/s 410066 Rev C (June 2009) 7-13 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | CAPSTONE C200 MICROTURBINE TECHNICAL REFERENCE
PDF Search Title:
CAPSTONE C200 MICROTURBINE TECHNICAL REFERENCEOriginal File Name Searched:
410066C_C200_Tech_Ref.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)