PDF Publication Title:
Text from PDF Page: 007
Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Protective Relay Functions for Capstone MicroTurbines Table 2. Over Voltage Protective Function Parameters Display Mode RS-232 Grid Connect Menu Parameter Description Parameter Value Default Command Over Voltage If the voltage on any phase rises above this setting for greater than Over Voltage Time, the system will shut down. Under Voltage to 528 V (L-L) 524 OVRVLT Over Voltage Time Establishes the time period allowed for any phase voltage to rise above the Over Voltage limit. 0.3 to 10 seconds 1.90 OVLTTM Fast Over Voltage The system will cease to export power to the grid within 1 msec if any phase voltage rises above this voltage for greater than Fast Over Voltage Time. Over Voltage to 634 V (L-L) 600 FSTOVL Fast Over Voltage Time Establishes the time period allowed for any phase voltage to rise above the Fast Over Voltage limit. 0.03 to 1.000 seconds 0.032 OVFSTM Over/Under Frequency (Protective Function 81 O/U) The Over Frequency is adjustable from Under Frequency to 65 Hz; in 0.1 Hz increments (Default = 60.5 Hz). The time period is adjustable from 0.06 to 10.00 seconds in 0.01 second increments (Default = 0.09 seconds) The UL1741 requirement for Over Frequency function is: Thedeviceshouldceasetoenergizetheoutputwithin6cycleswhenthegrid frequency is higher than 60.5 Hz. The Under Frequency is adjustable from 45 Hz to Over Frequency, in 0.1 Hz increments. (Default = 59.3 Hz). The time period is adjustable from 0.06 to 10.00 seconds in 0.01 second increments. (Default = 0.09 seconds) The UL1741 requirement for Under Frequency function is: Thedeviceshouldceasetoenergizetheoutputwithin6cycleswhenthegrid frequency is lower than 59.3 Hz. Asshipped,eachPowerControlleristestedtoverifythatitmeetstheUL1741 requirement to initiate a Grid Fault Shutdown, if the line frequency is greater than 60.5 Hz or is less than 59.3 Hz for a duration of 100 ms. The Over Frequency trip limit may be adjusted downwards as indicated in Table 3 and still comply with UL1741. The Under Frequency trip limit may be adjusted upwards as indicated in Table 3 and still comply with UL1741. The duration to trip may also be adjusted downwards as indicated in Table 3 and still comply with UL1741. 410033 Rev. D (February 2006) Page 7 of 10 This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the equipment specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Technical Reference Protective Relay Functions for Capstone MicroTurbines
PDF Search Title:
Technical Reference Protective Relay Functions for Capstone MicroTurbinesOriginal File Name Searched:
Capstone_Protective_Relays1.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)