Table 1-1. Capstone 60 Microturbine Specifications (Source: Capstone Turbine Corporation) SRI/USEPA-GHG-VR-27 September 2003 Dimensions Weight Electrical Inputs Electrical Outputs Noise Level Fuel Pressure Required Fuel Heat Content Heat Recovery Potential at Full Load Emissions (full load) Width Depth Height Microturbine only Power (startup) Communications Power at ISO conditions 60 oF at sea level Typical reported by Capstone w/o natural gas compressor w/ natural gas compressor Higher heating value Exhaust gas temperature Exhaust energy available for heat recovery Nitrogen oxides (NOX) Carbon monoxide (CO) Total hydrocarbon (THCs) 30 in. 77 in. 83 in. 1,671 lb Utility grid Ethernet IP or modem 60 kW, 400-480 VAC, 50/60 Hz, 3-phase 70dBAat33ft 75 psig 0.5 to 15 psig 970 to 2615 Btu/scf 580 oF 541,000 Btu/hr, LHV basis <9ppmvat15% O2 <40ppmvat15%O2 <9ppmvat15%O2 Electrical Performance at Full Load (natural gas) Heat input Power output Efficiency - with natural gas compressor Heat rate 811,000 Btu/hr, Natural gas-HHV 60 kW ± 1 kW 28% ± 2%, ISO conditions, LHV basis 12,200 Btu/kWh, LHV basis Table 1-2. Unifin MG2 Heat Exchanger Specifications (Source: Unifin International, Inc.) Weight Dimensions Heat Exchanger Efficiency Exhaust Design Temperature Tubeside Design Temperature Tubeside Design Pressure Design Heat Input Output 1.3. TEST FACILITY DESCRIPTION 820 lb 34.75”(W) x 48.5”(D) x 70.1875”(H) > 90% (at full load at water inlet temperature = 120 °F) 700 °F for C60 220 or 275 °F, closed-loop 150 psig 541,000 Btu/hr 375,000 Btu/hr at 180 oF return fluid temperature The verification of the Capstone 60 microturbine system was conducted at the Waldbaums’ Supermarket (constructed in 2002) and pictured in Figure 1-3. This new supermarket was originally a 35,000-sq. ft. retail facility. It was gutted to the block walls, expanded, and totally rebuilt into a 57,000-sq. ft. supermarket. It recently opened in July 2002. The store uses energy-efficient T4 light fixtures, so the load in the sales area is about 1.2 watts per square foot. The facility electric demand is never expected to drop below 200 kW in this store. The 480-volt power generated by the microturbine is wired directly into the store's 480-volt main panel. This unit was integrated in July 2002 with a 20,000-cfm Munters Drycool air-handling unit previously installed at Waldbaums in order to use the available heat from the Capstone 60 kW microturbine CHP system. The Munters unit provides cooling and heating to the main sales areas of the store. The unit also includes a desiccant section to provide dehumidification. The 1-5PDF Image | Environmental Technology Verification Report
PDF Search Title:
Environmental Technology Verification ReportOriginal File Name Searched:
Capstone-ETV-Report.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)