Capstone Capstone Turbine Corporation 6025 Yolanda Avenue Tarzana, CA 91356 1.4.5 Modem Commands LINENO Line test for modem communication MODEMS Modem state string Table 12 - Modem Commands. 1.4.6 Discrete Signal Commands OUTRLY Queries and sets the active state (open or close) and function assigned to the output relays located on the UCB. (password required only when changing value) Table 13 - Discrete Signal Commands. 1.4.7 Control Data Commands “-d” None “-s” None “d+” None None None None 1.5.51 1.5.66 1.5.72 String Description Args User Maint Reference String Description Args User Maint Reference INPFLT Queries and sets the enable, fault severity level, and fault detection time for the fault input signals located on the UCB. (password required only when changing value) “d+” None None 1.5.38 String Description Args User Maint Reference AUTOLD AUTRST CNTACC DSPFMT EALMOD ENGMOD FSTOVL FSTUVL FUELI1 FUELI2 MBAUDR MEDBTU MINPWR Query/Set the SA auto-loading feature (password required only when changing value) Queries or Sets the Auto Restart value (NO/YES) (password required only when changing value) Displays the device number that has access to setting the control data values. Queries/Sets the Display Format (password required only when changing value) Queries/Sets the External Auxiliary Load Mode (password required only when changing value). Queries/Sets the Engine Performance Mode (password required only when changing value). Queries/sets the fast over voltage power setting (Password required only when changing value) Queries/sets the fast under voltage power setting (Password required only when changing value) Adjustable fuel index 1. (password required only when changing value) Adjustable fuel index 2. (password required only when changing value) Queries/Sets the maintenance port baud rate (password required only when changing value) Queries/Sets the Medium BTU mode (Normal/Medium/Low) (password required only when changing value) Queries/Sets the minimum power that must be available when operating in a standalone multipac “-2d” Protected “-2d” Protected None “-2d” Protected "-2d" Protected "-2d" Protected “-2d” Protected “-2d” Protected “-2f” Protected “-2f” Protected “-4d” Protected “-2d” Protected "-4d" Protected Protected Protected None Protected Protected Protected Protected Protected Protected Protected Protected Protected Protected 1-10 1.5.4 1.5.5 1.5.15 1.5.20 1.5.21 1.5.24 1.5.28 1.5.29 1.5.30 1.5.31 1.5.64 1.5.65 1.5.66

PDF Image | Engineering Specification Communication Protocol

PDF Search Title:

Engineering Specification Communication Protocol

Original File Name Searched:

ES0325_DPC_User_Maint_Comm_Maint.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)