Behavior of Capstone and Honeywell Microturbine Generators During Load Changes Consultant Report

PDF Publication Title:

Behavior of Capstone and Honeywell Microturbine Generators During Load Changes Consultant Report ( behavior-capstone-and-honeywell-microturbine-generators-duri )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 011

Behavior of Capstone and Honeywell Microturbine Generators During Load Changes Microturbine Performance (High-pressure and low-pressure natural gas): • Full Load Power • Efficiency (LHV) • Heat Rate (LHV) Emissions (natural gas fuel): • NOx Other: • Noise level • Fuel flow (natural gas - HHV) • Exhaust gas temperature • Total exhaust energy • Dimensions • Weight • V oltage 30 kW (HP unit), 28 kW (LP unit) at ISO conditions, 59 degrees F, sea level 27 % +/- 2 points (HP Unit), 26% +/- 2 points (LP Unit) 12,600 Btu/kWh (HP Unit), 13,000 Btu/kWh (LP Unit) <9 ppmV / 6.7 g/hr / 0.0147 lb/hr 65 dBA @ 10 meters 410,000 Btu/hr / 428,000 kj/hr 520 degrees F / 271 degrees C 277,000 Btu/hr / 295,000 kj/hr (base @ 59 deg. F / 15 deg. C) 74.8”Hx28.1”Wx52.9”D 1900 mm H x 714 mm W x 1344 mm D 1052 lbs / 478 kg 400 - 480 VAC, 3 phase, 4 wire wye or 3 wire wye, ungrounded delta, 43 A max The Capstone MTG is designed to operate at constant temperature for best efficiency and lowest emissions. The power output of the turbine is varied by changing the turbine speed. The ramping rate of the turbine is limited by flame stability in the combustor, according to Capstone engineers. The fastest possible ramp up from 0 to full load takes about 10 seconds. The current unit should be able to ramp from 0 to full load in about 30 seconds while in grid-connect mode and about 20 seconds while in stand-alone mode. Although the current unit cannot vary power factor while in grid-connect mode, new software available in 2001 will allow power factor adjustment. The current unit is not able to change from grid-connect to stand-alone mode without a complete shutdown. Work is being done to design the unit so it can make this transition without shutting down. 2.2.2 The Honeywell Parallon Microturbine The Parallon microturbine operates much like the Capstone MTG. The Parallon’s specifications include: Microturbine Performance (with low-pressure natural gas): • Full Load Power • Efficiency (LHV) Emissions (natural gas fuel): • NOx (at 15% O2) 75 kW gross (not including the compressor load) at ISO conditions, 59 degrees F, sea level, +/- 0.75 PF 27.5 % not including gas compressor and transformer <50 ppm full power 59 degrees F, sea level 4

PDF Image | Behavior of Capstone and Honeywell Microturbine Generators During Load Changes Consultant Report

PDF Search Title:

Behavior of Capstone and Honeywell Microturbine Generators During Load Changes Consultant Report

Original File Name Searched:

2004-05-24_500-04-021.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)