Technical Reference Advanced Power Server (APS)

PDF Publication Title:

Technical Reference Advanced Power Server (APS) ( technical-reference-advanced-power-server-aps )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 020

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Advanced Power Server (APS) Table 3. Optional Module Wiring Specifications Module Specifications Wiring Specifications DC Input/Relay Output Module (Figure 9) Inputs (4): 12-24 VDC sinking/sourcing with one common Outputs (3): 6-27 VDC/6–240 VAC relay outputs with one common Note: This module must be placed in slot #3 on the PLC. Analog Current Input Module (Figure 10) 16-22 AWG Torque terminal screw connectors to 3.45 in-lb (0.39 Nm). Recommended screwdriver size 0.4T x 2.5W mm. 16-28 AWG Torque terminal screw connectors to 4.50 in-lb (0.51 Nm). Recommended screwdriver size 0.4T x 2.5W mm. 16-28 AWG Torque terminal screw connectors to 4.50 in-lb (0.51 Nm). Recommended screwdriver size 0.4T x 2.5W mm. 16-28 AWG Torque terminal screw connectors to 4.50 in-lb (0.51 Nm). Recommended screwdriver size 0.4T x 2.5W mm. 16-28 AWG Torque terminal screw connectors to 4.50 in-lb (0.51 Nm). Recommended screwdriver size 0.4T x 2.5W mm. 16-28 AWG Torque terminal screw connectors to 4.50 in-lb (0.51 Nm). Recommended screwdriver size 0.4T x 2.5W mm. Page 20 of 143 Input (1): Inputs (8): 24 VDC power with return 0-20 mA with three common for shield wiring. Note: Analog Current Output Module (Figure 11) Use shielded wiring as shown in Figure 10. DO NOT ground shield at both the module and the transmitter. Input (1): Outputs (8): 24 VDC power with return 4-20 mA with three common for shield wiring. Note: Use shielded wiring, and ground shield at common on module. Analog Voltage Input Module (Figure 12) Input (1): Inputs (8): 24 VDC power with return 0-10 VDC with three common for shield wiring. Note: Analog Voltage Output Module (Figure 13) Use shielded wiring, and ground shield at transmitter. DO NOT ground shield at both the module and the transmitter. Input (1): Outputs (8): 24 VDC power with return 0-10 VDC with three common for shield wiring. Note: Use shielded wiring, and ground shield at common on module. RTD Input Module (Figure 14) Inputs (4): Input channels with return. Also, five Note: Note: common for shield wiring. Use shielded wiring, and ground shield at common on module. Use the same type of wires and the same length of wire for all leads of an RTD device. Unused channels require jumpers installed from terminals CH+ to CH- to COM. 410079 Rev. C (December 2013) Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

PDF Image | Technical Reference Advanced Power Server (APS)

PDF Search Title:

Technical Reference Advanced Power Server (APS)

Original File Name Searched:

410079C_TR_APS-145.pdf

DIY PDF Search: Google It | Yahoo | Bing

Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info

Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info

Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info

Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info

BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info

Publications: Capstone Turbine publications for microturbine and distributed energy More Info

FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info

CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info

Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info

CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)