Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Technical Reference: Dual Mode System Controller (DMSC) Adjustable Settings Settings that are adjustable by the user are described in Table 1. Table 1. Undervoltage Relay Adjustable Settings Parameter Settings UVR Dial Undervoltage 80 to 95% of nominal voltage (Suggested setting = 85%) The UVR trips when the average of all three lines is less than the adjusted setpoint for a period longer than the adjustable time delay. UNDERVOLTAGE Nominal Voltage 208, 220, 230, 240, 400, 440, 460, 480 V This must be set to the actual three-phase voltage before line voltage is applied to the DMSC. DO NOT adjust this setting with line voltage applied. NOMINAL VOLTAGE Phase Unbalance 2 to 10%, DISABLE (Suggested setting = 10%) The UVR trips when any one of the three phases deviates from the average of all three phases by more than the adjusted setpoint. The Disable setting turns off phase unbalance protection for installations where voltage fluctuations cause nuisance tripping. UNBALANCE Undervoltage Time Delay Setting 0.1 to 20 seconds (Suggested setting = 3 sec) The UVR trips if an undervoltage condition lasts longer than the time period of this setting. TIME DELAY UNDER- VOLTAGE Time Delay Restart 1 to 300 seconds (Suggested setting = 30 sec) This setting should be the required time period for the relay to wait before energizing after a fault has been cleared. TIME DELAY RESTART 410071 Rev D (January 2010) Page 21 of 71 Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.PDF Image | Dual Mode System Controller DMSC
PDF Search Title:
Dual Mode System Controller DMSCOriginal File Name Searched:
410071D_Dual_Mode_System_Controller_DMSC_TR.pdfDIY PDF Search: Google It | Yahoo | Bing
Capstone Turbine and Microturbine: Capstone microturbines used and new surplus for sale listing More Info
Consulting and Strategy Services: Need help with Capstone Turbine, sizing systems, applications, or renewable energy strategy, we are here to assist More Info
Container Lumber Dry Kiln: Since 1991 developing and innovating dry kilns using standard shipping containers More Info
Supercritical CO2 Lumber Dry Kiln: Compact fast drying in 3 days or less for small amounts of wood and lumber drying More Info
BitCoin Mining: Bitcoin Mining and Cryptocurrency... More Info
Publications: Capstone Turbine publications for microturbine and distributed energy More Info
FileMaker Software for Renewable Energy Developing database software for the renewable energy industry More Info
CO2 Gas to Liquids On-Demand Production Cart Developing a supercritical CO2 to alcohol on-demand production system (via Nafion reverse fuel cell) More Info
Stranded Gas for low cost power Bitcoin Mining Using stranded gas for generators may provide breakthrough low power costs for cryptocurrency miners. More Info
CONTACT TEL: 608-238-6001 Email: greg@globalmicroturbine.com (Standard Web Page)